2E GDC, 12V, 100Ah, GEL

კოდი: 2E-GDC12-100
-უკან დაბრუნება
შემდეგი
ტექნიკური პარამეტრები 2E GDC, 12V, 100Ah, GEL:
მთავარი მახასიათებლები
მთავარი მახასიათებლების სრული სია
A type GEL VRLA
Rated voltage 12 V
The nominal capacity 100 Ah (С10)
Тип электролита GEL
Maximum discharge current 800 A (5 second)
The weight 29.5 kg (можливе відхилення ваги – до 5%)
Dimensions (LxWxH) mm 172 x 328 x 215
Main characteristics
A type GEL VRLA
Rated voltage 12 V
The nominal capacity 100 Ah (С10)
Maximum charge current 20A
Type of terminals М8
Number of charge-discharge cycles D.O.D. 30% - до 1200 циклов
D.O.D. 50% - до 600 циклов
D.O.D. 100% – до 300 циклов
Тип электролита GEL
Additionally
Maximum discharge current 800 A (5 second)
The optimum operating temperature 25°C±3°C
+15°С-+25°С /рекомендуемый диапазон температур эксплуатации
Self-discharge at 20°C (% per month) 3
Емкость батареи (для С10) 102% +40°C
85% 0°C
65% -15°C
Physical characteristics
Life time 5 years /в буферном режиме
Colour black
The weight 29.5 kg (можливе відхилення ваги – до 5%)
Dimensions (LxWxH) mm 172 x 328 x 215
შეფუთვის პარამეტრები
სიგანე 190 მილიმეტრი
სიმაღლე 270 მილიმეტრი
სიგრძე 360 მილიმეტრი
წონა 30.50 კგ
მოცულობა 0.0185 მ3
გარანტია
გარანტია 12 თვე
In a world where stable power supply is critical for security, IT infrastructure, and industrial processes, choosing a high-capacity battery is an investment in peace of mind. The 2E GDC 12V 100 Ah battery has been designed with this approach in mind: maximum reliability, long service life, and full compliance with requirements for buffered operation.
652 ლარი*
ხელმისაწვდომია
 
* საშუალო ფასი ბაზარზე
GEL Technology: Stability Without Compromise

This model belongs to the VRLA (Valve Regulated Lead Acid) class, but with a gel electrolyte that significantly improves its performance characteristics. The GDC series batteries utilize AGM-GEL technology, providing high resistance to deep discharge, minimizing the risk of plate degradation, and ensuring safe, sealed, maintenance-free operation. They are ideal for powering IT and telecommunications equipment, data centers, and are a better solution for solar and wind power stations and off-grid energy systems. The GDC batteries comply with IEC60896-21/22 (for stationary installations) and IEC61427-1/2 (for photovoltaic solar systems) standards.

Maximum Energy Density in a Stable Housing

With a capacity of 100 Ah (C10), the battery provides long-lasting power for critical systems. Its maximum discharge current reaches 800 A (for 5 seconds), ensuring reliable system startups even under sudden peak loads. The maximum charging current is 20 A, guaranteeing efficient recharging without overheating or shortening the battery’s lifespan.

Despite its 30 kg weight (±5% deviation), the battery retains compactness for its class, with dimensions of 215 × 328 × 172 mm, allowing it to fit in standard cabinets and enclosures. The package includes M8 bolts for connections.

Lifespan of up to 15 Years: Durability with Consideration of Cycling

In buffered operation mode, the battery can last up to 10 years, but it is also capable of withstanding a moderate number of charge/discharge cycles. It is important to consider that the depth of discharge (DOD) directly impacts the battery's lifespan:

  • At 30% DOD: up to 1,200 cycles
  • At 50% DOD: up to 600 cycles
  • At 100% DOD: up to 300 cycles

This shows that GEL technology is effective for buffered use, but it is not intended for frequent deep discharges. For this reason, the battery is not recommended for use in off-grid or mobile systems, where cycling is constant.

Temperature Parameters: Adaptive Performance

The recommended temperature range for operation is +15°C to +25°C, as it provides the highest stability and longevity for the battery. However, it remains functional even under more extreme conditions. The battery's capacity changes depending on the temperature:

  • 102% at +40°C
  • 85% at 0°C
  • 65% at -15°C

This performance profile makes the battery versatile for use in indoor environments, technical rooms, and telecommunications systems.

Adhering to Guidelines for Long-Term Operation

Despite its high potential, it is crucial to adhere to the recommended operating conditions:

  • Do not use the battery outside the recommended mode.
  • Always fully recharge the battery after discharge.
  • Calculate the overall system capacity according to the battery class and load specifications.

It is also important to consider the self-discharge rate, which is only 3% per month at 20°C, ensuring long service life without loss of functionality.

  • GEL (VRLA) Technology
  • Capacity: 100 Ah (C10)
  • Service life up to 15 years in buffered operation mode
  • Discharge current: 800 A for 5 seconds
  • Maximum charge current: 20 A
  • M8 terminal (bolts for connections included)
  • Cycle life at different depths of discharge (DOD):30% DOD: up to 1,200 cycles, 50% DOD: up to 600 cycles, 100% DOD: 300 cycles
  • Operating temperature range: -15°C to +40°C, optimal range: +15°C to +25°C
  • Capacity depending on ambient temperature: 102% at +40°C, 85% at 0°C, 65% at -15°C
  • Low self-discharge rate: 3% per month at 20°C
  • Compliant with IEC60896-21/22 and IEC61427-1/2 standards
  • Dimensions: 215 × 328 × 172 mm
  • Weight: 30 kg (±5%)